25W Single Output Switching Power Supply         MS-25 series

Low price and high reliability
105
output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
Compact size, light weight
100% full-load burning test
Installed with EMI filter, minimum wave

SPECIFICATIONS

OUTPUT

Model

MS-25-5

MS-25-12

MS-25-15

MS-25-24

DC Voltage

5V

12V

15V

24V

Rated Current

5A

2.1A

1.7A

1.1A

Current Range

0-5A

0-2.1A

0-1.7A

0-1.1A

Rated Power

25W

25.2W

25.5W

26.4W

Ripple & Noise

50mVp-p

100mVp-p

100mVp-p

100mVp-p

Voltage Adj.Range

+10,-5%

±10%

±10%

±10%

Voltage Tolerance

±2%

±1%

±1%

±1%

Inlet Stability

±0.5%

±0.5%

±0.5%

±0.5%

Load Stability

±1%

±0.5%

±0.5%

±0.5%

Setup, Rise, Hold Up Time

800ms,50ms,10ms/115VAC   300ms,50ms,80ms/230VAC

INPUT

Voltage Range

85~132VAC/170~264VAC selected by switch   47~63Hz; 240~370VDC

AC Current

0.7A/115V   0.30A/230V

Efficiency

 72%/115VAC

 76%/115VAC

77%/115VAC

 80%/115VAC

Inrush Current

Cold-start current 15A/115V   30A/230V 

Leakage Current

<0.75mA/240VAC

PROTECTION

Over Load

105%~150%

Protection type: plusing hiccup shutdown Reset:auto recovery

ENVIRONMENT

Working Temp., Humidity

-10~+60(Refer to output derating curve), 20%~90%RH

Storage Temp., Humidity

-20~+85,10%~95%RH

Temp. Coefficient

+-0.03%/°C(0~50°C)

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

SAFETY

Withstand Voltage

I/P-O/P: 1.5KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

UL1012TUV EN60950(IEC950,UL1950)Approved

EMC Standard

CLSPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification

OTHERS

Dimension

85*58*38mm(L*W*H)

Weight

0.2Kg

NOTE

1.The testing condition for the parameter above is: 230VAC input, rated load, 2570% RH.Humidity.

2.Error.include the setting error,line stability and load stability.

3.Wave test:adopting “A12”double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.

Popular Searches

Website on alibaba.com: http://leyuelec.preview.alibaba.com

Aliexpress.com Store: http://www.aliexpress.com/store/509864

Home  |  About Us  |  News  |  Products  |  Certificate  |  Download  |  Inquiry  |  Contact Us

Yueqing Leyu Electric Automation co.,Ltd .    ADD:Huarong Road, liushi Town, Yueqing City, Zhejiang, China
TEL: 86-577-62980983 62998958     Mobile:86-13757759294    FAX: 86-577-62981651

现金抢庄牛牛